{"product_id":"ametra-petri","title":"Ametra Petri Benchtop Spectrophotometer","description":"\u003c!-- STYLES FOR HEADINGS, BUTTONS, \u0026 MODAL POPUPS --\u003e\n\u003cstyle\u003e\n  \/* GLOBAL TYPOGRAPHY COLOR FIX FOR DAWN OVERRIDES *\/\n  .product-description-body,\n  .product-description-body *,\n  .product-description-body p,\n  .product-description-body h1,\n  .product-description-body h2,\n  .product-description-body h3,\n  .product-description-body h4,\n  .product-description-body li,\n  .product-description-body td,\n  .product-description-body span {\n    color: #000000 !important;\n    opacity: 1 !important;\n  }\n\n  \/* REVERT TABLE HEADERS \u0026 BUTTON HOVERS TO WHITE TEXT *\/\n  .product-description-body th {\n    color: #ffffff !important;\n  }\n  .product-description-body .btn-cta {\n    color: #000000 !important;\n  }\n  .product-description-body .btn-cta:hover {\n    color: #ffffff !important;\n  }\n  .product-description-body .ametra-submit-btn {\n    color: #ffffff !important;\n  }\n  .product-description-body .ametra-submit-btn:hover {\n    color: #000000 !important;\n  }\n  .product-description-body .disclaimer-text,\n  .product-description-body .disclaimer-text * {\n    color: #555555 !important;\n  }\n  \n  \/* MODAL OVERLAY \u0026 CONTAINER *\/\n  .ametra-modal-overlay {\n    display: none;\n    position: fixed;\n    top: 0;\n    left: 0;\n    width: 100%;\n    height: 100%;\n    background-color: rgba(0, 0, 0, 0.6);\n    z-index: 99999;\n    align-items: center;\n    justify-content: center;\n  }\n  .ametra-modal {\n    background: #ffffff;\n    border: 2px solid #000000;\n    width: 90%;\n    max-width: 500px;\n    padding: 30px;\n    position: relative;\n    box-shadow: 0 10px 25px rgba(0,0,0,0.2);\n  }\n  .ametra-modal h3 {\n    text-transform: uppercase;\n    font-weight: 800;\n    margin-bottom: 20px;\n    font-size: 1.4rem;\n  }\n  .ametra-close-btn {\n    position: absolute;\n    top: 15px;\n    right: 20px;\n    background: none;\n    border: none;\n    font-size: 1.5rem;\n    font-weight: bold;\n    cursor: pointer;\n    color: #000000 !important;\n  }\n  .ametra-form-group {\n    margin-bottom: 15px;\n    display: flex;\n    flex-direction: column;\n  }\n  .ametra-form-group label {\n    font-size: 0.8rem;\n    text-transform: uppercase;\n    font-weight: 700;\n    margin-bottom: 5px;\n  }\n  .ametra-form-group input, \n  .ametra-form-group textarea {\n    border: 1px solid #000000;\n    padding: 12px;\n    font-size: 1rem;\n    outline: none;\n    background: #ffffff;\n  }\n  .ametra-form-group textarea {\n    resize: vertical;\n    min-height: 100px;\n  }\n  .ametra-submit-btn {\n    width: 100%;\n    background: #000000;\n    border: 2px solid #000000;\n    padding: 14px;\n    text-transform: uppercase;\n    font-weight: 700;\n    cursor: pointer;\n    letter-spacing: 0.05em;\n    margin-top: 10px;\n    transition: background 0.2s, color 0.2s;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"product-description-body\"\u003e\n  \u003c!-- CTA BLOCK 1 --\u003e\n  \u003cdiv class=\"cta-block\"\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('quoteModal')\"\u003eRequest Quote\u003c\/button\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/7300\/9979\/files\/Ametra_Petri_Benchtop_Spectrophotometer.pdf?v=1787638502\" download=\"Ametra_Petri_Benchtop_Spectrophotometer.pdf\" target=\"_blank\" class=\"btn-cta\"\u003eDownload Presentation\u003c\/a\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('expertModal')\"\u003eAsk an Expert\u003c\/button\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- DEVICE DESCRIPTION --\u003e\n  \u003csection\u003e\n    \u003ch2\u003eProduct Overview\u003c\/h2\u003e\n    \u003cdiv class=\"desc-text\"\u003e\n      \u003cp\u003e\u003cstrong\u003eBenchtop Spectrophotometer with Record 2-Inch Aperture:\u003c\/strong\u003e Measure heterogeneous samples with unprecedented accuracy. Not all product samples come in neat, flat, homogeneous units. Pellets, powders, particles, rough surfaces, fabrics, food, and natural materials are inherently non-uniform. Standard small-aperture instruments deliver inconsistent readings that fail to reflect the true overall color of these complex materials.\u003c\/p\u003e\n      \u003cp\u003eThe \u003cstrong\u003eAmetra Petri Benchtop Spectrophotometer\u003c\/strong\u003e features a record-breaking 2-inch (50 mm) diameter measurement aperture—the largest available in its class. This unique design averages color measurement across uneven, particulate, and heterogeneous sample surfaces, delivering reliable, repeatable color data for difficult-to-measure materials. Operable autonomously via an iPad-sized 7\" color touchscreen or connected to a PC for advanced quality workflow integration.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"desc-grid\"\u003e\n      \u003cdiv class=\"desc-card\"\u003e\n        \u003ch4\u003eTarget Audience\u003c\/h4\u003e\n        \u003cul\u003e\n          \u003cli\u003eColor matchers \u0026amp; color matching technicians\u003c\/li\u003e\n          \u003cli\u003eColorists \u0026amp; tint specialists\u003c\/li\u003e\n          \u003cli\u003eColor quality control technicians \u0026amp; engineers\u003c\/li\u003e\n          \u003cli\u003eManufacturing quality engineers with color focus\u003c\/li\u003e\n          \u003cli\u003eColor development \u0026amp; lab technicians\u003c\/li\u003e\n          \u003cli\u003eQC lab technicians \u0026amp; technical service specialists\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"desc-card\"\u003e\n        \u003ch4\u003eKey Capabilities\u003c\/h4\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRecord 50 mm (2-Inch) Aperture:\u003c\/strong\u003e Maximum measurement area for true optical averaging of non-uniform samples.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eAutonomous \u0026amp; Connected Operation:\u003c\/strong\u003e High-resolution 7\" color touch screen for standalone use or PC integration via SQCX software.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003ePASS\/FAIL Judgment:\u003c\/strong\u003e Instant tolerance verification, target standard storage, and verbal color difference reporting.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eSpecialized Indices:\u003c\/strong\u003e Dedicated food and industrial indices including Coffee roast, SCAA, HCCI, BCU, Tomato a\/b, FTCI, TPS, TSS, TCS, TJS, and Lycopene.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"desc-card\"\u003e\n        \u003ch4\u003eBusiness Impact \u0026amp; Applications\u003c\/h4\u003e\n        \u003cul\u003e\n          \u003cli\u003e\n\u003cstrong\u003eReliable Quality Control:\u003c\/strong\u003e Eliminate guesswork and spot-reading variance on heterogeneous materials to prevent costly quality escapes and customer rejection.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eRaw Material to Finished Goods:\u003c\/strong\u003e Gain clear color visibility across raw powders, pellets, and finished goods to maintain strict brand standards.\u003c\/li\u003e\n          \u003cli\u003e\n\u003cstrong\u003eVersatile Applications:\u003c\/strong\u003e Plastics and electronics, paints and inks, textiles and apparel, commercial printing, ceramics, and food industries.\u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- CTA BLOCK 2 --\u003e\n  \u003cdiv class=\"cta-block\"\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('quoteModal')\"\u003eRequest Quote\u003c\/button\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/7300\/9979\/files\/Ametra_Petri_Benchtop_Spectrophotometer.pdf?v=1787638502\" download=\"Ametra_Petri_Benchtop_Spectrophotometer.pdf\" target=\"_blank\" class=\"btn-cta\"\u003eDownload Presentation\u003c\/a\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('expertModal')\"\u003eAsk an Expert\u003c\/button\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS TABLE --\u003e\n  \u003csection\u003e\n    \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n    \u003cdiv class=\"table-wrapper\"\u003e\n      \u003ctable\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n            \u003cth style=\"width: 30%;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"width: 70%;\"\u003eSpecification Details\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eAmetra Petri Benchtop Spectrophotometer\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003ePrice\u003c\/td\u003e\n            \u003ctd\u003e$1,450.00\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eMeasuring Geometry | Specular Component\u003c\/td\u003e\n            \u003ctd\u003e45°\/0° | –\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eLight Source | Lifespan\u003c\/td\u003e\n            \u003ctd\u003eLED | \u0026gt; 2,000,000 measurements\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eAperture | Targeting | Speed | Averaging\u003c\/td\u003e\n            \u003ctd\u003e50.00 mm (2 in) aperture | Aperture targeting | 1.0 sec measurement time | Averaging\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSpectral Range | Interval\u003c\/td\u003e\n            \u003ctd\u003e400–700 nm | 10 nm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eStandard Observer | Illuminants\u003c\/td\u003e\n            \u003ctd\u003e2° \u0026amp; 10° Standard Observer | D65, A, C illuminants\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eRepeatability | Inter-Instrument Agreement\u003c\/td\u003e\n            \u003ctd\u003eRepeatability: 0.03 | Inter-Instrument Agreement: 0.35\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eColor Spaces | Difference | Indices\u003c\/td\u003e\n            \u003ctd\u003eCIE L*a*b, HunterLab | ΔEab, ΔE(Hunter) | SCAA, HCCI, Coffee roast, BCU, Tomato a\/b, FTCI, TPS, TSS, TCS, TJS, Lycopene\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eDisplay \u0026amp; Storage\u003c\/td\u003e\n            \u003ctd\u003e7\" Color Touch Screen | Displays Color Values, Numerical \u0026amp; Verbal Color Difference, Pass\/Fail Indication | Stores up to 1,000 Standards and 30,000 Samples\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eInterface \u0026amp; Power\u003c\/td\u003e\n            \u003ctd\u003eUSB, Bluetooth | 24V DC, 3A adapter\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSize \u0026amp; Weight\u003c\/td\u003e\n            \u003ctd\u003e210 × 245 × 188 mm [8.27 × 9.65 × 7.40 in] | 3,100 g [6.83 lbs]\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSoftware\u003c\/td\u003e\n            \u003ctd\u003eBundled SQCX Fully Functional Color Control Software | Optional PeColor Ai Formulation Software\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- COMPETITIVE COMPARISON TABLE --\u003e\n  \u003csection\u003e\n    \u003ch2\u003eCompetitive Comparison\u003c\/h2\u003e\n    \u003cdiv class=\"table-wrapper\"\u003e\n      \u003ctable\u003e\n        \u003cthead\u003e\n          \u003ctr\u003e\n            \u003cth style=\"width: 25%;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"width: 25%;\"\u003eAmetra Petri Benchtop Spectrophotometer\u003c\/th\u003e\n            \u003cth style=\"width: 25%;\"\u003eHunterLab ColorFlex L2\u003c\/th\u003e\n            \u003cth style=\"width: 25%;\"\u003eKonica Minolta CM-5\u003c\/th\u003e\n          \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003ePrice\u003c\/td\u003e\n            \u003ctd\u003e\u003cstrong\u003e$1,450.00\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd\u003e$13,340.00\u003c\/td\u003e\n            \u003ctd\u003e$15,000.00\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eMeasuring Geometry | Specular Component\u003c\/td\u003e\n            \u003ctd\u003e45°\/0° | –\u003c\/td\u003e\n            \u003ctd\u003e45°\/0° | –\u003c\/td\u003e\n            \u003ctd\u003ed:8° | SCI \/ SCE switchable\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eLight Source | Lifespan\u003c\/td\u003e\n            \u003ctd\u003eLED | \u0026gt; 2,000,000 measurements\u003c\/td\u003e\n            \u003ctd\u003eXenon flash lamp | 10 years\u003c\/td\u003e\n            \u003ctd\u003ePulsed xenon lamp | –\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eAperture | Targeting | Speed\u003c\/td\u003e\n            \u003ctd\u003e\n\u003cstrong\u003e50.00 mm (2 in)\u003c\/strong\u003e | Aperture | 1.0 sec | Averaging\u003c\/td\u003e\n            \u003ctd\u003e25.04 mm (1 in) | Camera with liveview | 1.0 sec | Averaging\u003c\/td\u003e\n            \u003ctd\u003e36.00 mm (1.4 in) | Aperture | 1.0 sec | Averaging\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSpectral Range | Interval\u003c\/td\u003e\n            \u003ctd\u003e400–700 nm | 10 nm\u003c\/td\u003e\n            \u003ctd\u003e400–700 nm | 10 nm\u003c\/td\u003e\n            \u003ctd\u003e360–740 nm | 10 nm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eObserver \u0026amp; Illuminants\u003c\/td\u003e\n            \u003ctd\u003e2° \u0026amp; 10° | D65, A, C\u003c\/td\u003e\n            \u003ctd\u003e2° \u0026amp; 10° | A, C, D50, D55, D65, D75, F02, F07, F11\u003c\/td\u003e\n            \u003ctd\u003e2° \u0026amp; 10° | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eRepeatability | Inter-Instrument Agreement\u003c\/td\u003e\n            \u003ctd\u003e0.03 | 0.35\u003c\/td\u003e\n            \u003ctd\u003e0.05 | 0.15\u003c\/td\u003e\n            \u003ctd\u003e0.04 | 0.15\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eColor Spaces \u0026amp; Indices\u003c\/td\u003e\n            \u003ctd\u003eCIE L*a*b, HunterLab | ΔEab, ΔE(Hunter) | SCAA, HCCI, Coffee roast, BCU, Tomato a\/b, FTCI, TPS, TSS, TCS, TJS, Lycopene\u003c\/td\u003e\n            \u003ctd\u003eCIE L*a*b, Hunter Lab, CIE LCh, CIE Yxy, CIE XYZ | ΔE, ΔE2000, ΔH, ΔC*, ΔEcmc | E313 WI\/Tint, E313 YI, D1925 YI, Opacity, Color Strength, Gray Scale, Metamerism, HCCI, SCAA, Tomato indices\u003c\/td\u003e\n            \u003ctd\u003eL*a*b, LCh, Hunter Lab, Yxy, XYZ, Munsell | ΔEab, ΔE*94, ΔE00, ΔE(Hunter), CMC | MI, WI (E313), YI (E313\/D1925), ISO Brightness\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eDisplay \u0026amp; Storage\u003c\/td\u003e\n            \u003ctd\u003e7\" color touch screen | Shows Color Values, Numerical \u0026amp; Verbal Difference, Pass\/Fail | 1,000 Standards \/ 30,000 Samples\u003c\/td\u003e\n            \u003ctd\u003e7\" Color LCD Touch Screen | Shows Color Values, Difference, Pass\/Fail | Up to 1,000,000 records max\u003c\/td\u003e\n            \u003ctd\u003e5.7\" TFT color LCD | Shows Color Values, Difference, Pass\/Fail | 1,000 Standards \/ 4,000 Samples\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eInterface \u0026amp; Power\u003c\/td\u003e\n            \u003ctd\u003eUSB, Bluetooth | 24V DC, 3A adapter\u003c\/td\u003e\n            \u003ctd\u003e2 USB, HDMI, Ethernet, Foot switch | 90–240 VAC @ 24VDC\/3.75A\u003c\/td\u003e\n            \u003ctd\u003eUSB 1.1, RS-232C | AC 100–240V adapter\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSize \u0026amp; Weight\u003c\/td\u003e\n            \u003ctd\u003e210 × 245 × 188 mm [8.27 × 9.65 × 7.40 in] | 3,100 g [6.83 lbs]\u003c\/td\u003e\n            \u003ctd\u003e160 × 210 × 240 mm [6.30 × 8.27 × 9.45 in] | 2,750 g [6.06 lbs]\u003c\/td\u003e\n            \u003ctd\u003e385 × 192 × 261 mm [15.16 × 7.56 × 10.28 in] | 5,800 g [12.79 lbs]\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003ctd class=\"param-header\"\u003eSoftware\u003c\/td\u003e\n            \u003ctd\u003eBundled SQCX Color Control Software | Optional PeColor Ai Formulation Software\u003c\/td\u003e\n            \u003ctd\u003eBundled Essentials 2.0 QC Software\u003c\/td\u003e\n            \u003ctd\u003eOptional SpectraMagic NX\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003c!-- CTA BLOCK 3 --\u003e\n  \u003cdiv class=\"cta-block\"\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('quoteModal')\"\u003eRequest Quote\u003c\/button\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0822\/7300\/9979\/files\/Ametra_Petri_Benchtop_Spectrophotometer.pdf?v=1787638502\" download=\"Ametra_Petri_Benchtop_Spectrophotometer.pdf\" target=\"_blank\" class=\"btn-cta\"\u003eDownload Presentation\u003c\/a\u003e\n    \u003cbutton type=\"button\" class=\"btn-cta\" onclick=\"openModal('expertModal')\"\u003eAsk an Expert\u003c\/button\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- LEGAL \u0026 TRADEMARK DISCLAIMER --\u003e\n  \u003cdiv class=\"disclaimer-text\"\u003e\n    \u003cp\u003e\u003cstrong\u003eTrademarks \u0026amp; Legal Notice:\u003c\/strong\u003e All product names, logos, brands, trademarks, and registered trademarks mentioned on this page are the property of their respective owners. Their use on this page does not imply any affiliation with, sponsorship by, or endorsement by these trademark holders.\u003c\/p\u003e\n    \u003cp\u003eAll product specifications and pricing details were compiled from open sources and manufacturer documentation available at the time of publication. All information is provided for comparative reference only and is subject to change, errors, and omissions without notice.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- MODAL POPUPS HTML --\u003e\n  \u003cdiv id=\"quoteModal\" class=\"ametra-modal-overlay\"\u003e\n    \u003cdiv class=\"ametra-modal\"\u003e\n      \u003cbutton type=\"button\" class=\"ametra-close-btn\" onclick=\"closeModal('quoteModal')\"\u003e×\u003c\/button\u003e\n      \u003ch3\u003eRequest Quote\u003c\/h3\u003e\n      \u003cform id=\"quoteForm\" onsubmit=\"handleFormSubmit(event, 'quote')\"\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eName *\u003c\/label\u003e\n          \u003cinput type=\"text\" id=\"quoteName\" required placeholder=\"John Doe\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eCompany\u003c\/label\u003e\n          \u003cinput type=\"text\" id=\"quoteCompany\" placeholder=\"Company Name\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eEmail *\u003c\/label\u003e\n          \u003cinput type=\"email\" id=\"quoteEmail\" required placeholder=\"john@company.com\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003ePhone\u003c\/label\u003e\n          \u003cinput type=\"tel\" id=\"quotePhone\" placeholder=\"+1 (555) 000-0000\"\u003e\n        \u003c\/div\u003e\n        \u003cbutton type=\"submit\" class=\"ametra-submit-btn\"\u003eSubmit Request\u003c\/button\u003e\n      \u003c\/form\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv id=\"expertModal\" class=\"ametra-modal-overlay\"\u003e\n    \u003cdiv class=\"ametra-modal\"\u003e\n      \u003cbutton type=\"button\" class=\"ametra-close-btn\" onclick=\"closeModal('expertModal')\"\u003e×\u003c\/button\u003e\n      \u003ch3\u003eAsk an Expert\u003c\/h3\u003e\n      \u003cform id=\"expertForm\" onsubmit=\"handleFormSubmit(event, 'expert')\"\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eName *\u003c\/label\u003e\n          \u003cinput type=\"text\" id=\"expertName\" required placeholder=\"John Doe\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eCompany\u003c\/label\u003e\n          \u003cinput type=\"text\" id=\"expertCompany\" placeholder=\"Company Name\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eEmail *\u003c\/label\u003e\n          \u003cinput type=\"email\" id=\"expertEmail\" required placeholder=\"john@company.com\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003ePhone\u003c\/label\u003e\n          \u003cinput type=\"tel\" id=\"expertPhone\" placeholder=\"+1 (555) 000-0000\"\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"ametra-form-group\"\u003e\n          \u003clabel\u003eYour Question *\u003c\/label\u003e\n          \u003ctextarea id=\"expertQuestion\" required placeholder=\"Type your technical question here...\"\u003e\u003c\/textarea\u003e\n        \u003c\/div\u003e\n        \u003cbutton type=\"submit\" class=\"ametra-submit-btn\"\u003eSend Question\u003c\/button\u003e\n      \u003c\/form\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- MODAL SCRIPT LOGIC --\u003e\n  \u003cscript\u003e\n    function openModal(modalId) {\n      document.getElementById(modalId).style.display = 'flex';\n    }\n    function closeModal(modalId) {\n      document.getElementById(modalId).style.display = 'none';\n    }\n    window.onclick = function(event) {\n      if (event.target.classList.contains('ametra-modal-overlay')) {\n        event.target.style.display = 'none';\n      }\n    }\n    function handleFormSubmit(event, type) {\n      event.preventDefault();\n      let name, company, email, phone, question, subject, body;\n      \n      if (type === 'quote') {\n        name = document.getElementById('quoteName').value;\n        company = document.getElementById('quoteCompany').value;\n        email = document.getElementById('quoteEmail').value;\n        phone = document.getElementById('quotePhone').value;\n        \n        subject = encodeURIComponent(\"New Quote Request - Ametra Petri Benchtop Spectrophotometer\");\n        body = encodeURIComponent(`Name: ${name}\\nCompany: ${company}\\nEmail: ${email}\\nPhone: ${phone}\\nProduct: Ametra Petri Benchtop Spectrophotometer`);\n      } else {\n        name = document.getElementById('expertName').value;\n        company = document.getElementById('expertCompany').value;\n        email = document.getElementById('expertEmail').value;\n        phone = document.getElementById('expertPhone').value;\n        question = document.getElementById('expertQuestion').value;\n        \n        subject = encodeURIComponent(\"Ask an Expert Inquiry - Ametra Petri Benchtop Spectrophotometer\");\n        body = encodeURIComponent(`Name: ${name}\\nCompany: ${company}\\nEmail: ${email}\\nPhone: ${phone}\\n\\nQuestion:\\n${question}`);\n      }\n      \n      window.location.href = `mailto:vdozhdalev@ametra.ai?subject=${subject}\u0026body=${body}`;\n      closeModal(type === 'quote' ? 'quoteModal' : 'expertModal');\n      event.target.reset();\n    }\n  \u003c\/script\u003e\n\u003c\/div\u003e","brand":"Ametra","offers":[{"title":"Default Title","offer_id":51550024728891,"sku":"AMBSLA01","price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/7300\/9979\/files\/Ametra_Petri_Benchtop_Spectrophotometer_Logo_on_Screen.jpg?v=1788331339","url":"https:\/\/ametra.ai\/products\/ametra-petri","provider":"Ametra","version":"1.0","type":"link"}